Broadband BBG MAX Gel Battery for Telecom

Broadband BBG MAX Gel Battery for Telecom

  • Broadband BBG MAX Gel Battery for Telecom
New

Broadband BBG MAX Gel Battery

Exceptional longevity and reliable operation

These advanced telecom batteries feature a gelled electrolyte that dissipates heat more effectively. They have a catalyst-enhanced design, resulting in lower float current and improved long-term efficiency. Designed specifically for broadband applications, BBG MAX batteries meet the demanding requirements of CATV Outside Plant (OSP) network sites, providing dependable backup power to support critical infrastructure and network reliability.

BAttery Quick Facts
Battery type

VRLA GEL (VRLA)

capacity

180 - 220 Runtime Minutes

design life

12 Years

operating environment

Indoor Outdoor Controlled Outdoor Uncontrolled

Certifications & Compliances

TAA Compliant UL 1989 Compliant

industries

Features & Benefits

Extended service life: Gelled electrolyte combined with a catalyst helps maximize battery life and deliver long-lasting performance.

Reliability: Gel technology delivers dependable performance in extreme environments, including the harshest operating conditions.

Support sustainability: Lower your energy demand and cooling costs. Broadband MAX batteries are 98% recyclable, and manufactured with up to 80% recycled materials.

Reduced operational expenses: Exceptional battery life extends replacement intervals, minimizing site visits and improving operational efficiency.

  • MSE Pure Lead technology reduces water loss by up to 50%, lowers float current, and improves grid life to help extend battery service life.
  • Gelled electrolyte delivers superior thermal management for enhanced performance in demanding environments.
  • Premium materials and components, including a rugged polypropylene case, provide long-term reliability and protection in harsh operating conditions.
  • Extended shelf life with storage capability of up to 18 months for VRLA GEL models.
    12-volt monobloc design incorporating Valve Regulated Lead Acid (VRLA) and Gelled Electrolyte (GEL) technologies.

BBG MAX Broadband Battery

ModelVoltageRuntime Minutes to 24 Amps @77°F (25°C) to 1.75 VPCMaximum Discharge CurrentShort Circuit CurrentLength inches (mm)Width inches (mm)Height inches (mm)Weight lbs. (kg)
BBG-180MAX12V180800 Amps2300 Amps12.50 (318)6.83 (174)8.05 (205)63 (29)
BBG-195MAX12V195800 Amps2500 Amps13.42 (341)6.80 (173)8.48 (215)66 (30)
BBG-220MAX12V220800 Amps2600 Amps13.42 (341)6.80 (173)8.48 (215)73 (33)